ELECTRONIC LEAK DETECTION


INSTRUCTIONS (pdf)
FLIER (pdf)
55200
“INSPECTOR” 2 IN 1 ELECTRONIC / UV LEAK DETECTOR

This revolutionary new design allows the user to perform Electronic and UV Leak Detection all with one tool. The “INSPECTOR” offers six levels of sensitivity (15 levels of detection) with a tri-colored LED indicator. This allows the “INSPECTOR” to pin-point leaks as small as 1/10 oz per year. The ultra bright UV light is built into the end of the probe allowing easy access into tight areas. Incorporating both electronic and UV technology into one unit insures that even the toughest leaks can be found. (patent # 6,647,761)

FEATURES:
Ultra Bright UV/Blue LED Light
Detects Leaks As Small As 1/10 oz Per Year
Mute Function
Detects All Refrigerants, CFC’S,HCFC’S, HFC’S
Tri-Colored Visual Leak Level Indicator
6 Levels Of Sensitivity (15 Levels OfDetection)
UV Safety Glasses
Includes Custom Molded Case

Part# Description
53515-B LED Bulb for 55200, 55300 & 55400


INSTRUCTIONS (pdf)
FLIER (pdf)
55100
ELECTRONIC LEAK DETECTOR

The 55100 offers an accurate and reliable solution to Electronic Leak Detection.

FEATURES:
3 Levels Of Sensitivity (5 Levels Of Detection)
Visual Leak Level Indicator
Detects Leaks As Small As 1/10 oz Per Year
Detects All Refrigerants, CFC’S, HCFC’S, HFC’S
Includes a Custom Molded Carrying Case


Part# Description
55100-SEN Sensor Tip for 55100, 55200, 55300 & 55400


INSTRUCTIONS (pdf)
55300
COMPLETE ELECTRONIC & UV LEAK DETECTION KIT

55310 – Same as 55300 (with 10 Application Dye Cartridge)

This kit offers the “INSPECTOR” along with our UV Dye Injection System. Our cartridge type dye injector is fast and easy to use. Just twist the handle to inject the appropriate amount of dye. The 55300 kit is the ultimate solution for all your A/C leak detection needs.

FEATURES:
55200 “INSPECTOR” Electronic Leak Detector
UV Dye Injector W/25 Application Dye Cartridge
Dye Injector Connection Hose W/R12 Adapter
Dye Cleaner & UV Safety Glasses

55400
COMPLETE ELECTRONIC & UV LEAK DETECTION KIT

This kit offers the “INSPECTOR” along with our UV Dye Injection System. Our refillable dye injector is fast and easy to use. Just twist the handle to inject the appropriate amount of dye. The 55400 kit is the ultimate solution for all your A/C leak detection needs.

FEATURES:
55200 “INSPECTOR” Electronic Leak Detector
Refillable Dye Injector
Dye Injector Connection Hose W/R12 Adapter
2 oz Bottle of Concentrated Universal Dye
UV Safety Glasses & Dye Cleaner


INSTRUCTIONS (pdf)
FLIER (pdf)
55500
ELECTRONIC LEAK DETECTOR W/HEATED SENSOR

55500-220
Electronic Leak Detector W/220V Battery Charger

Mastercool broadens it’s line by introducing it’s NEW Heated Sensor Electronic Leak Detector. The HEATED SENSOR technology delivers fast and accurate results while eliminating non-refrigerant false alarms. The flexible 15” probe has a patented UV Blue Light built into the tip allowing dual UV and Electronic Leak Detection. Made in USA (patent# 6,647,761)

FEATURES:
Six Sensitivity Levels
Automatic Warm Up
Meets and Exceeds SAE J1627
Dual-colored Visual LED Leak Size Display
Detects all Refrigerants (CFC’s, HCFC’s, HFC’s)
Rechargeable Ni-MH Battery
Low Battery Indicator
High Volume Pump
Blue UV LED Light
Reset Function

SPECIFICATIONS:
Operating Temp: 32º to 125ºF
Power Supply: 2 C-Size 1.5V Ni-MH Battery
Battery Life: 8 hrs per cycle (1000 cycles)
Warm-Up Time: 25 Seconds
Ultimate Sensitivity: 1/10 oz per year
Probe/Core Length: 15”
Dimension: 7” x 7”
Weight: 1.10 lbs

Part# Description
53515-B LED Bulb for 55500
55500-SEN Replacement Sensor


INSTRUCTIONS (pdf)
FLIER (pdf)
55750
COMBUSTIBLE GAS LEAK DETECTOR

55750-220
Combustible Gas Leak Detector W/220V Battery Charger

Mastercool introduces it’s new hand-held combustible gas leak detectors. Offering the most advanced sensor technology with a state-of-the-art microprocessor, these units detect leaks fast and accurately. The flexible 15” probe has a bright LED light built into the tip for easy viewing in hard to reach locations. The membrane switch panel offers easy one touch control and operation. Each of the six levels of sensitivity has an audible alarm and visual indicator to identify leak activity. These units include the newest rechargeable Ni-MH battery (nearly double the power of existing Ni-Cad batteries) and comes in a custom molded case. (patent# 6,647,761)

DETECTS: Acetone, Acetylene, Ammonia, Benzene, Butane, Butanol, Chlorine, Ethane, Ethanol, Gasoline, Hexane, Hydrogen, Hydrogen Sulfide, Isobutane, Methane (natural gas), Methanol, Methyl Acetate, Methyl Chloride, Methyl Ether, Naptha, N-Butane, Pentane, Propane, Propanol, Sulfer Dioxide and Trichloroethane

FEATURES:
Six Sensitivity Levels
Automatic Warm Up
Audible Leak Alarm & Visual Leak Size Indicator
Rechargeable Ni-MH Battery
Low Battery Indicator
Made in USA
Bright LED Light
Reset Function

SPECIFICATIONS:
Operating Temp: 32º to 125ºF
Power Supply: 2 C-Size 1.5V Ni-MH Battery
Battery Life: 8 hrs per cycle (1000 cycles)
Warm-Up Time: 25 Seconds
Ultimate Sensitivity: 50 – 1000 ppm
Probe/Core Length: 15”
Dimension: 7” x 7”
Weight: 1.10 lbs