Product Description
THIS ITEM IS NO LONGER AVAILABLE
With the 4-Way Digital Manifold, Mastercool is showing its determination to become the leader in this sector of the industry. Taking the experience gained with the 2-Way Digital Manifold the 4-Way model not only offers a 4-valve option but it also allows for a multitude of interactive PC enhanced functions and the capability of 24 hours of data logging.
- Record and store up to 24 hours of data and up to 15 jobs
- Large Easy to Read LCD
- Displays Pressures, Saturated, Actual, Superheat and Subcool Temperatures
- Over 60 Refrigerants
- Clamp-on Thermocouple Connector displays Actual Temperature and Automatically Calculates Superheat or Subcool Temperature
- Vacuum Sensor Cable displays Deep Vacuum
- Ball valve design includes 3/8” bore through the block for increased flow
SPECIFICATIONS:
- Class 1.0 standard gauge reading
- Pressure Display: PSI, INHg, Bar, MPa, Kg/cm2
- Temperature Display: °F or °C
- Deep Vacuum Display: Micron, mBar, KPa, Pa, Torr, mTorr, mmHg
- Sensing Resolution: 1 psi (.07 Bar, .007 MPa, .07 Kg/cm2)
- Sensing Accuracy: ±1 psi or 1% of reading (whichever is greater)
- Working Pressure: 0 to 750 psi (52 Bar, 5 MPa, 52 Kg/cm2) (does not display 0-5 psi)
- Proof Pressure: 1000 psi (70 Bar, 7 MPa, 70 Kg/cm2) (Tolerable pressure without internal damage)
- Refrigerant Temperature Range: -40 to 200°F (-40 to 93°C)
- Operating Temperature: 32 to 122°F (0 to 45°C)
- Temperature Accuracy: ±1˚F (±0.5˚C) between 32 to 160˚F (0 to 71˚C)
- Storage Temperature: 10 to 120˚F (-12 to 49˚C)
- Connections: 1/4” M-Flare
- Power: 9V DC battery with optional AC/DC adapter
- Battery Life: 30-36 hours pressure and temperature mode only (continuous use) / 25-30 hours vacuum or backlight mode (continuous use)
- Auto-Off: 15 min. with disabling capability
Easily update refrigerants:
New refrigerants can be updated with a USB connection and Mastercool Software.
Refrigerants: R12, R22, R23, R32, R113, R114, R115, R116, R123, R124, R134, R134a, R141B, R142B, R143, R143a, R152a, R290, R401A, R401B, R404A, R407A, R407B, R407C, R407D, R407F, R409A, R410A, R410B, R411A, R411B, R412A, R413A, R414A, R414B, R417A, R422A, R422B, R422C, R422D, R427A, R434A, R437A, R438A, R441A, R448A, R449A, R452A, R455A, R501, R502, R503, R504, R507A, R508B, R509A, R600, R600A, R601, R601A, R744
Mastercool’s 4-Way Digital Manifold Recording Function:
- Records and stores data directly into the manifold memory
- Records up to 24 hours of data or 15 jobs before having to download
- Downloads data at a rate 115 kb per second (24 hrs of data = approx. 15 min of download time)
- Uses Mastercool’s Data Logger Application to easily view data
Mastercool Data Logger Application:
- Display data in “real time” using a USB connection, computer and software
- Platform: Windows 2000, XP, Windows Vista and Windows 7
- Log Customer Name, Date and Technician’s Name
- Recorder/Cursor Function Features
- (1) Recorder TIME command. Record in intervals of 5, 15 min, 1, 4, 8 and 24 hrs
- (2) Recorder ON/OFF command
- (3) ZOOM: NORMAL, 5X or 10X. Use the zoom option to view specific data points of interest
- (4) The Time-Line measures the selected recording time. Moving the cursor along the timeline easily displays specific plot points
- The Data Logger program uses the Units information (Kg/cm2, BAR, Mpa, PSI, ˚C, and ˚F) contained in each data bit on the manifold and displays these units on the screen
- Display Function Features
- (1) Display ALL command. This enables all parameters of the Digital Manifold to be displayed simultaneously. As the line functions propagate across the screen, the “real-time” data will also be displayed digitally
- (2) Monitor specific functions of interest. The Data Logger continues to record all the functions in the background, regardless of how many individual functions are being displayed
- (3) Display DEEP VACUUM ONLY command. This enables only the deep vacuum readings to be displayed on the screen.
- (4) View ANALOG GAUGES function enables the user to represent the Digital Manifold data in the form of high and low pressure analog gauges.
99961: HVAC 4-Way Digital Manifold gauge set includes manifold with a set of 3-60” (150 cm) ball valve hoses with manual shut-off valves and one black vacuum hose, vacuum sensor with cable, clamp-on thermocouple, data logger CD and USB cable
99972: HVAC 4-Way Digital Manifold gauge set includes manifold with a set of 3-72” (180 cm) ball valve hoses with manual shut-off valves and one black vacuum hose, vacuum sensor with cable, clamp-on thermocouple, data logger CD and USB cable
99961-EU: HVAC 4-Way Digital Manifold gauge set includes manifold with a set of 3-60” (150 cm) ball valve hoses with manual shut-off valves and one black vacuum hose, vacuum sensor with cable, clamp-on thermocouple, 2 straight adapter fittings (90413), data logger CD and USB cable
99963-EU: HVAC 4-Way Digital Manifold gauge set includes manifold with a set of 3-72” (150 cm) ball valve hoses with manual shut-off valves and one black vacuum hose, clamp-on thermocouple, 2 straight adapter fittings (90413), data logger CD and USB cable
* Manifolds assembled with teflon gasket hoses, add a -T
* Manifolds assembled with ball valve at the end of hoses, add a -E
OPTIONAL ACCESSORIES:
52336: Clamp-on Thermocouple (extends 3 ft)
52337: Clamp-on Thermocouple (extends 10 ft)
90413: R410A Straight Adapter 1/4 FL-M x 5/16 Swivel-F
90411: 1/4 x 5/16 R410A Ball Valve Adapter
99333: 1/4 FL-M x 1/4 FL-M x 1/4 FL-F Tee
90413: R410A Straight Adapter 1/4 FL-M x 5/16 Swivel-F
90430: 1/4 x 1/4 Swivel Ball Valve
90433: 1/4 x 5/16″ Swivel Ball Valve
99334-110: 110 V AC/DC Adapter
99334-220: 220 V AC/DC Adapter
98062:Vacuum Sensor and Cable Assembly (6.5 ft)
99903-PBA: Plastic Carrying Case
99332: 1/8 NPT x 1/4-FL Flare Swivel Adapter